The most powerful excimer laser in the AMARIS family: 1050 Hz, active 7D eye tracking and an ablation time of 1.3 seconds per dioptre.¹ Supplied, installed, trained and serviced in the UK and Ireland by Instinctive.

Make An Enquiry Order codes & brochures ↓ Technical detail at SCHWIND ↗
SCHWIND AMARIS 1050RS excimer laser
1050 Hz
pulse rate
7D
active eye tracking
1.3 s
per dioptre¹
Touch-free
SmartSurfACE
Authorised UK & Ireland distributor
Instinctive Servicing

Laser-trained engineers across the UK and Ireland

Instinctive employs its own team of SCHWIND-trained laser engineers, based across the UK and Ireland. Installation, preventive maintenance, calibration, gas changes, software updates and breakdown response are carried out by Instinctive engineers under manufacturer protocols.

Discuss service cover 01234 302233
Installation & commissioning
Site survey, delivery, installation and acceptance testing.
Planned maintenance
Scheduled preventive maintenance and annual technical safety checks.
Breakdown response
UK-based engineers dispatched from regional locations.
Software & upgrades
SCHWIND CAM releases, licence activation and platform upgrades.
Parts & gas
Genuine SCHWIND parts and premix gas held in the UK.
Application support
Clinical application specialists for treatment planning and new procedures.
In use

Case Studies

Optimal Vision, Birmingham
Optimal Vision · Birmingham
Upgrading A Single-Theatre Refractive List

Moving from a 500 Hz platform to the 1050RS cut average treatment time to under two seconds per dioptre and added four cases to a standard theatre day.

Vision Care Collective, Manchester
Vision Care Collective · Manchester
One Protocol Across Three Sites

A shared SCHWIND CAM plan and one wetlab programme let three clinics run identical protocols, with surgeons rotating between sites without re-training.

Testimonials

“The handover was the part I expected to hurt. Two wetlabs and a week of on-site support later, we were running full lists on the 1050RS.”

Adeel Rahman
Mr Adeel Rahman FRCOphth
Refractive Lead, Optimal Vision Birmingham

“Instinctive answer the phone. When a consumable order or a service question comes up across our three sites, it is dealt with the same day.”

Claire Donnelly
Ms Claire Donnelly
Clinic Director, Vision Care Collective
Ordering

Order Codes & Consumables

Licences and consumables are ordered through Instinctive. Send the code, or tell us the indication, and we confirm price, lead time and stock.

Item
Ordered
AMARIS PresbyMAX
Presbyopic treatment licence
Per treatment
ATOS LASIK
Femtosecond flap procedure
Per treatment
SmartSight lenticule
Lenticular extraction licence
Per treatment
Patient interface rings
Single use, boxed and sized
Per box

Orders and re-orders: info@instinctive.vision or 01234 302233

Downloads

Brochures & Data Sheets

SCHWIND literature for the AMARIS 1050RS. Enter your name, clinic and email and the PDF downloads straight away.

AMARIS 1050RS product brochure
Platform overview, technologies and clinical applications
PDF · EN
AMARIS 1050RS technical data sheet
Full specification, dimensions and site requirements
PDF · EN
SCHWIND CAM planning brochure
ORK-CAM, PresbyMAX and PTK-CAM modules
PDF · EN
SmartSurfACE patient information
Touch-free TransPRK explained for patients
PDF · EN
Full Technical Detail From SCHWIND
SCHWIND publish the full specifications and clinical data. Instinctive handles supply, installation, training, consumables and service.
SCHWIND Product Page ↗
Hire & rental partner
Per-Use Hire With MobilEyes
Mobile laser theatre and per-procedure hire across the UK and Ireland, handled directly by MobilEyes.
Visit MobilEyes ↗
Close-up of the AMARIS 1050RS laser area
Why surgeons choose it

Benefits at a glance

High performance laser for refractive and therapeutic corneal surgery
Fast ablation of 1.3 seconds per dioptre* can contribute to patient safety and comfort
Unique 7D eye tracking
SCHWIND CAM offers broad range of applications
Gentle & incision-free treatment with SmartSurfACE
Convenience for doctor and patient through swivel laser arm
User friendly design and high-gloss finish
*LASIK, without astigmatism, 12.5 HSA, 6 mm optical zone
Speed

Innovative and reliable

A repetition rate of 1050 Hz, currently one of the highest of any excimer laser on the market, brings ablation time down to 1.3 seconds per dioptre.² Shorter treatment means less risk of corneal dehydration and a shorter time for the patient to fixate on the green light.

² LASIK myopia without astigmatism, 12.5 mm vertex distance, 6 mm optical zone
AMARIS product family: ablation time per dioptre
SCHWIND AMARIS product family: ablation time per dioptre (s / D)
“The clinical results with the SCHWIND AMARIS laser are the best I have ever seen.”
Michiel Luger, MD · Bergman Clinics, Utrecht
Eye model visualising the seven tracked dimensions
Precision

Safety in up to seven dimensions

The 1050 Hz eye tracker actively compensates for every eye movement in five to seven dimensions: lateral, rolling, cyclotorsion, pupil-centre shift and the time factor itself.

Latency-Free Tracking, the 7th dimension

The tracker analyses previous eye positions during treatment and calculates where the corneal target will be at the next two pulses. The scanner moves there before the pulse fires, so ablation is free of latency error.

Planning

Plan individually for each situation

Every treatment is different. The modular SCHWIND CAM software plans each case across an exceptionally wide range of corneal surgery, incorporating corneal or ocular wavefront, pachymetry and epithelial data so no detail relevant to the individual ablation is left out.

SCHWIND CAM and modules →
SCHWIND CAM treatment planning structure
ORK-CAM module
ORK-CAM

Intelligent planning for wide-ranging, tailor-made refractive treatment. Aspheric profiles for aberration-free and customised treatments based on corneal or ocular wavefront data.

PresbyMAX module
PresbyMAX

Safe, efficient treatment of emmetropic, myopic, hyperopic and astigmatic patients with limited accommodation, using bi-aspheric ablation profiles.

PTK-CAM module
PTK-CAM

Therapeutic treatments: superficial and deep corneal scars and degenerations localised and ablated in circular, elliptical or individual shapes, superficial or deep for laser keratoplasty.

SmartSurfACE
Touch-free treatment

SmartSurfACE

No suctionNo bladeNo incision

SmartSurfACE combines touch-free TransPRK surface treatment with SmartPulse Technology. Vision is corrected through the top layers of the cornea in a single step, and the epithelium is removed more precisely and uniformly than with manual or alcohol-assisted debridement. Suitable for any laser candidate as well as patients with thin corneas, corneal pathologies or complex topographies.

SCHWIND technologies →
SCHWIND AMARIS 1050RS with EVO patient bed
Built in

Further advantages

Intelligent Thermal Effect Control (ITEC)

Corneal temperature monitoring and laser pulse sorting for minimum heating and very gentle ablation.

Automatic Fluence Level Adjustment (AFLA)

Balanced pulse number and energy: fast treatment with high corneal smoothness.

Integrated slit lamp

Immediate postoperative control down to the deep layers of the cornea.

Corneal Collagen Crosslinking lamp

Integrated in the workflow, ready to use immediately with no additional adjustment.

Swivelling laser arm and powered swivelling bed

Comfort and convenience for patient, doctor and assistants.

Treatment Assistant Manager (TAM)

Controlled sequence of light intensity, microscope magnification and fixation points; each step individually adjustable.

Integrated plume evacuation

Plume evacuation and filter for clean operating theatre air.

Automatic video record of treatment

Teaching, reviewing and marketing possibilities.

Gentle at speed

AFLA and ITEC

Automatic Fluence Level Adjustment
AFLA: an ideal balance

About 80 percent of the ablation runs at high fluence. For the remaining 20 percent of fine modelling, Automatic Fluence Level Adjustment switches to a lower fluence, giving optimum corneal smoothing even at the highest ablation speed.

Heat propagation of a laser pulse with ITEC
ITEC: gentle even at the highest speeds

Intelligent Thermal Effect Control distributes pulses in a thermally optimised, dynamically adapted sequence so each position on the cornea has time to cool. Infrared thermography confirms the tissue heats only minimally at high ablation speeds.*

Corneal temperature measurements with an infrared thermographic camera
Measured in vivo

Corneal temperature sequence captured with an infrared thermographic camera during trans-epithelial treatment.

“The thermal control technology and ablation control with two fluence levels play a very important role, especially in biological terms: the less the biological interaction with the corneal tissue, the more reliably wounds can heal.”
Prof. Jorge Alió · Vissum, Alicante
* High-speed recording of thermal load during laser trans-epithelial corneal refractive surgery using a 750 Hz ablation system. De Ortueta D, Arba-Mosquera S, Magnago T. J Optom. 2019.
Usage areas

Clinical Applications

Refractive and therapeutic corneal surgery, across these usage areas.

Illustration — refractive corrections
Pathway
Refractive Corrections
Myopia & myopic astigmatism
LASIK, touch-free TransPRK, or SmartSight lenticular extraction with the ATOS.
Hyperopia & hyperopic astigmatism
Transition zones scale with the magnitude of the correction.
Mixed astigmatism
Corneal and ocular wavefront data combined in a single plan.
Illustration — presbyopia treatment zones
Pathway
Presbyopia
PresbyMAX
Bi-aspheric presbyopic correction, licensed per treatment.
Monocular & binocular planning
Planned in SCHWIND CAM alongside the distance correction.
Illustration — therapeutic cornea profile
Pathway
Therapeutic
PTK-CAM
Phototherapeutic keratectomy for surface pathology.
Irregular corneas
Corneal wavefront-guided treatment of irregular surfaces.
Retreatment
Planning from corneal topography where refraction alone is unreliable.
Evidence

Published Papers & Articles

Surgeon-authored reports on AMARIS outcomes, published by SCHWIND eye-tech-solutions. Ask us for the full literature list for a specific indication.

Astigmatism · Treatment planning
Vector Planning with the SCHWIND AMARIS 1050RS
Noel Alpins AM, MD — New Vision Clinics, Melbourne, Australia
09.2017 · Read the report ↗
Hyperopia · LASIK · Surface treatments
LASIK for high hyperopia with the SCHWIND AMARIS
Laurent Gauthier, MD — Espace Helios, Saint Jean de Luz, France
09.2016 · Read the report ↗
All SCHWIND user reports ↗
Answers

Questions We Get Asked

Straight answers on the platform, what it treats, and how Instinctive supports it in the UK and Ireland.

What is the SCHWIND AMARIS 1050RS?

The SCHWIND AMARIS 1050RS is an excimer laser platform for refractive and therapeutic corneal surgery, manufactured by SCHWIND eye-tech-solutions in Germany. It runs at a 1050 Hz repetition rate, ablates in about 1.3 seconds per dioptre, uses a 0.54 mm laser spot and active 7D eye tracking, and is planned with SCHWIND CAM software.

Who supplies and services the AMARIS 1050RS in the UK and Ireland?+

Instinctive is the distributor for SCHWIND eye-tech-solutions in the UK and Ireland. Supply, installation, surgeon and staff training, consumables, treatment licences and engineer service cover are all handled by Instinctive on 01234 302233 or info@instinctive.vision.

What conditions can the AMARIS 1050RS treat?+

Myopia and myopic astigmatism, hyperopia and hyperopic astigmatism, mixed astigmatism, presbyopia through the PresbyMAX module, and therapeutic indications through PTK-CAM including irregular corneas. Treatment can be delivered as LASIK, as touch-free TransPRK surface treatment with SmartSurfACE, or with lenticular extraction when paired with the SCHWIND ATOS femtosecond laser.

How long does a treatment take on the AMARIS 1050RS?+

Ablation takes approximately 1.3 seconds per dioptre. Shorter time under the laser reduces the risk of corneal dehydration and loss of fixation, and allows more cases in a standard theatre list.

What is 7D eye tracking?+

SCHWIND’s active 7D eye tracker follows eye movement in seven dimensions, covering both static and dynamic cyclotorsion as well as lateral and rotational motion, and compensates for it during the ablation.

What is SmartSurfACE?+

SmartSurfACE is SCHWIND’s touch-free surface treatment: TransPRK combined with SmartPulse technology, performed in a single step with no suction ring, no cut and no flap. It is often chosen for thinner corneas and for patients in contact sports or dusty occupations.

Can we trial the laser before committing?+

Yes. Instinctive arranges hands-on demonstrations, wetlab sessions with SCHWIND application specialists, and visits to reference sites already running the platform. All three are booked through the enquiry form on this page.

Can we hire an AMARIS instead of buying one?+

Yes. Per-use hire and mobile laser theatre provision across the UK and Ireland is delivered by our partner MobilEyes, with the laser, consumables and a trained operator included. It is commonly used to build a list before committing to a capital purchase.

How do we order treatment licences and consumables?+

Treatment licences for PresbyMAX and the SCHWIND CAM modules, ATOS consumables, patient interface rings and SmartSight lenticule codes are ordered from Instinctive by email or telephone. Send the order code, or describe the indication, and we confirm price, lead time and stock.

What service and support cover is included?+

Every installation includes a planned preventative maintenance schedule, UK-based manufacturer-trained engineer cover and remote diagnostic support. Response times and cover hours are set in the service agreement.

How does the 1050RS differ from the AMARIS 750S and 500E?+

All three are part of the SCHWIND AMARIS family and share the SCHWIND CAM planning environment. The 1050RS is the fastest, at a 1050 Hz repetition rate with 7D eye tracking; the 750S and 500E run at lower repetition rates. Instinctive supplies all three in the UK and Ireland and can advise on the right fit for your case mix.

More From SCHWIND

View All SCHWIND Products
ATOS
Femtosecond laser
SCHWIND ATOS
AMARIS 750S
Excimer laser
AMARIS 750S
SIRIUS+
Diagnostics
SCHWIND SIRIUS+
PERAMIS
Diagnostics
SCHWIND PERAMIS
Enquiry

Talk To Instinctive

Tell us what you need on the AMARIS 1050RS: a demo, a wetlab place, a quote, consumables or service cover and we will reply within one working day. Or call 01234 302233.

I'm enquiring about
Hire ↗
Demo enquiry · SCHWIND AMARIS 1050RS
Which format?